Blackridge BR1000 2HP Air Compressor Instruction Manual

This product is a 2HP direct drive motor with a 21 liter tank size, including Nitto style fittings, perfect for most light duty air tools.


Blackridge BR1000 2HP Air Compressor Instruction Manual - cover page
Brand
Black Ridge
Category
Other
Document type
User Manual
Language
English
Pages
9
File format
PDF
File size
1.6 MB
Published
07 November, 2023
Updated
07 November, 2023
MD5 checksum
0DF13BDCB8D53B508E65AB8563C75B48

About this manual

The Blackridge BR1000 is a 2HP air compressor with a 21 L tank, a 240V AC 50 Hz electric motor, and a maximum tank pressure of 115 PSI (8 bar). It is supplied with an instruction manual that covers setup, assembly, running in, pressure adjustment, maintenance and troubleshooting.

The manual explains how to fit the oil breather and air filter, check oil level, attach the wheels and rubber stopper, use the Nitto style outlet, drain the tank, and check the safety valve. It also lists technical information such as 70 L/min free air delivery, 85 PSI pump kick-in pressure, SAE30 oil type, 75% duty cycle and an 80 dB noise rating at 5 m.

What's inside

  • Technical Information
  • Know Your Compressor
  • Pre Setup Checks
  • Assembly
  • You're In Control
  • Using Your Product
  • Maintenance
  • Troubleshooting
  • Warranty

Specifications

ModelBR1000
Voltage240 V AC, 50 Hz
Motor2 HP electric
Wattage1500 W
No load speed2800 RPM
Maximum tank pressure115 PSI (8 bar)
Adjustable outlet pressure0 PSI to 115 PSI
Pump kick-in pressure85 PSI
Tank size21 L
Duty cycle75%
Free air delivery70 L/min
Oil typeSAE30
Noise rating80 dB at 5 m
Number of outlets1

Frequently asked questions

What oil type should I use in the Blackridge BR1000 air compressor?

Use SAE30 oil.

What is the maximum tank pressure of the BR1000?

The maximum tank pressure is 115 PSI (8 bar).

How long is the warranty on the Blackridge air compressor?

It is warranted for 12 months from the date of purchase.

How do I lower the outlet air pressure?

If the pressure needs to be lower, turn anti-clockwise.

Download PDF (1.6 MB)