Servosan Kurtaran KGS-series Battery Powered Emergency Evacuation Device User's Manual

SERVOSAN ® KURTARAN® KGS-series BATTERY POWERED EMERGENCY EVACUATION DEVICE USER’S MANUAL


Servosan Kurtaran KGS-series Battery Powered Emergency Evacuation Device User's Manual - cover page
Brand
SERVOSAN
Category
Other
Document type
User Manual
Language
English
Pages
16
File format
PDF
File size
276 KB
Published
06 November, 2023
Updated
06 November, 2023
MD5 checksum
E95ECF398501D88C23598D76A15F6362

About this manual

The Servosan Kurtaran KGS-series is a battery-powered emergency evacuation device for elevators. According to the manual, it starts automatically when mains power fails and moves the cabin to the upper or lower floor to rescue people inside. The manual covers the INT9-V2 control unit, the SR battery charger, main controller connection, battery selection and connection, operation, program bridges, display indications, fault diagnosis and periodic maintenance.

The manual lists use for elevator motors up to 16 HP and battery arrangements using four 12 V 7 Ah batteries up to 8.2 HP or four 12 V 12 Ah batteries for 8.2–16 HP motors. It also gives a safety warning to turn off the W-automat and disconnect the 48+ battery terminal before maintenance.

What's inside

  • General
  • Technical Description
  • KURTARAN KGS Main Controller Connection
  • Battery Selection and KGS-Battery Connection
  • Operation
  • Program Bridges
  • DS Display
  • Warnings, Diagnoses and Corrections
  • Faults, Diagnoses and Repair
  • Periodical Maintenance

Specifications

Maximum elevator motor power16 HP
Battery configuration up to 8.2 HPFour 12 V 7 Ah batteries in series (48 V 7 Ah)
Battery configuration for 8.2–16 HPFour 12 V 12 Ah batteries
Maximum battery cable length150 cm
Minimum battery cable cross-section6 mm² (10 mm² for 8.2–16 HP motors)
Battery charger output voltageUp to 55.2 V when fully charged
Cabin lamp12 V, 3 W

Frequently asked questions

What happens when AC power fails?

The KGS starts automatically and moves the elevator cabin to the upper or lower floor to rescue people inside.

What should be done before maintenance work?

Turn off the W-automat on the KGS unit and disconnect the cable on the 48+ terminal on the battery.

How long does the cabin light remain on after successful evacuation if the power failure continues?

It remains on for two more minutes.

Which batteries are used for motors between 8.2 and 16 HP?

Four 12 V 12 Ah batteries must be used instead of 7 Ah batteries.

Download PDF (276 KB)