This document is a user manual for a Gram Commercial 765041782 commercial refrigerator.
This is the user manual (765041782 Rev. 000) for the Gram Commercial ECO MIDI KG/FG cabinet. It explains how to install, use and maintain the product, with sections on application, safety information, location, general description, electrical connection, general use, operating the product, temperature setting, keyboard lock, alarms, error codes on the display, troubleshooting, defrosting, defrost water, door closing mechanism, power failure, cleaning, door gaskets, long term storage, service, disposal, the EC-Declaration of conformity and a wiring diagram.
The manual states that the product is designed for storage of foodstuff at a constant temperature and may not be used for chilling or freezing of foodstuff. It gives an operating ambient temperature range of +16 °C to +40 °C, notes that the product is not to be used outdoor, that only the supplied cord may be used and that extension cords must never be used. It also covers handling after horizontal transport, leveling with adjustable legs or locking castors, and the 3-minute wait before switching the product on again.
| Operating ambient temperature | +16 °C to +40 °C |
|---|---|
| Intended use | Storage of foodstuff at a constant temperature |
| Refrigerant | R134a, R404A, R290, R600a |
| Minimum standing time after horizontal transport | 2 hours before start |
| Minimum wait before switching on again | 3 minutes |
It is designed for storage of foodstuff at a constant temperature and may not be used for chilling or freezing of foodstuff.
No, the manual states that the product is not to be used outdoor.
It is designed to operate in an ambient temperature between +16 °C and +40 °C.
It must stand upright for at least 2 hours before it is started, so the oil from the compressor can run back.
No, only the supplied cord is to be used and an extension cord must never be used for this appliance.