This document describes the features and specifications of the KO 16BK DECOR and KO 21BK DECOR gas water heaters.
This Portuguese technical manual covers the DECOR line gas water heaters KO 16BK DECOR and KO 21BK DECOR, in GLP and GN gas versions (1PFLP1, 1PFGN1). It opens with a specification table for both models: 16 and 21 L/min water flow, 22,500 kcal/h (26.2 kW) and 30,000 kcal/h (34.9 kW) nominal power, 2 s ignition time, water pressure from 1 to 60 m.c.a., dimensions of 32.9x60.1x15.9 cm, 11.8 kg net weight and 127~220V automatic bivolt power supply.
The manual then describes the front, rear, lower, upper and side views with their parts, the touch display and its keys, functions such as timer, solar function, turnback and optional wired remote control, structural features (glass front cover, copper heat exchanger, second-stage solenoid, water flow regulator) and protective devices including the over-temperature bimetal sensor, automatic ignition, pressure relief valve, flame detection sensor and flue obstruction detection. It ends with voltage selection notes, exploded views of both models, an error code table, a symptoms and solutions table, and the electrical diagram with connector voltages and resistances. This manual is written in Portuguese.
| Water flow (L/min, at +20º) | 16 (KO 16BK DECOR); 21 (KO 21BK DECOR) |
|---|---|
| Gas type | GLP or GN |
| Nominal power | 22,500 kcal/h (26.2 kW) / 30,000 kcal/h (34.9 kW) |
| Maximum gas consumption | 1.90 kg/h (GLP) / 2.36 m³/h (GN) for 16BK; 2.53 kg/h (GLP) / 3.15 m³/h (GN) for 21BK |
| Ignition time | 2 s |
| Water pressure | minimum 1 m.c.a.; ideal working >10 m.c.a.; maximum 60 m.c.a. |
| Dimensions LxHxD | 32.9 x 60.1 x 15.9 cm |
| Net weight | 11.8 kg |
| Power supply | 127~220V automatic bivolt |
| Power consumption | 35 Wh |
| Exhaust | Forced |
| Warranty | 3 years (check policy) |
They are available in GLP and GN gas versions, identified by the model suffixes 1PFLP1 and 1PFGN1.
The ignition time is 2 seconds for both models.
The maximum water pressure is 60 m.c.a., with a minimum of 1 m.c.a. and an ideal working pressure above 10 m.c.a.
E2 indicates absence of flame, which may be caused by lack of gas, incorrect pressure, the solenoid valves or the flame sensor.