This document is the instruction manual for WilTec 51185 and 51186 automatic incubators.
This is the Spanish-language instruction manual for the WilTec automatic incubator, articles 51185 and 51186. It opens with the manufacturer's contact and returns information, followed by an introduction and a list of safety instructions for using the device, including notes on the 230 V AC supply, the power cable and keeping the electrical connection away from moisture.
The manual then gives technical data for the incubator — display temperature range, temperature and humidity accuracy, power supply and environmental conditions — along with its functions such as adjustable temperature, humidity measurement, a fully automatic turning system and, for article 51185, an LED candling lamp. Further sections describe the suitable place for the incubator and give general information on incubation: storing eggs, preparing the device before use, disinfecting it and the incubation temperatures required for different bird species. This manual is written in Spanish.
| Display temperature range | 30–39.5 °C |
|---|---|
| Temperature measurement accuracy | ±0.1 °C |
| Humidity indicator display range | 1–99 % RH (relative humidity) |
| Humidity sensor accuracy | ±3 % RH |
| Power supply | 230 V / 50 Hz |
| Ambient relative humidity | 55–75 % |
| Ambient temperature | 17–25 °C |
| Maximum number of eggs | 56 chicken/duck eggs (51185 and 51186) |
| Article 51185 equipment | With LED candling lamp |
Eggs should not be stored for more than ten to twelve days, at a cool temperature of 8–15 °C and 75 % relative humidity.
It should run without eggs for at least 24 hours before use, and if possible for a week so that all settings can be checked.
Both articles hold a maximum of 56 chicken or duck eggs.
The room should be heated and ideally kept between 17 and 25 °C without large temperature swings.