AVL DiTEST VAS 6910 Module Balancer Operating Manual

The VAS 6910 Module Balancer is a tool used for automotive repair. It helps you quickly and easily replace modules on your car.


AVL DiTEST VAS 6910 Module Balancer Operating Manual - cover page
Brand
AVL DITEST
Document type
User Manual
Language
English
Pages
72
File format
PDF
File size
3.4 MB
Published
06 November, 2023
Updated
06 November, 2023
MD5 checksum
A0C2C3C96E939061D173EDD4D00E0653

About this manual

The VAS 6910 Module Balancer is a high‑voltage battery testing device intended for use in automotive workshops. The manual begins with extensive safety instructions, required qualifications and warnings about electrical hazards, flammable fumes and proper ventilation.

It then covers the components, commissioning steps, operating procedures, maintenance, troubleshooting, and detailed technical data such as power ratings, interfaces and environmental limits. The document ends with fault reporting forms and an index for quick reference.

What's inside

  • Safety Instructions
  • General Information
  • Components
  • Commissioning
  • Operation
  • Troubleshooting
  • Maintenance and Care
  • Technical Data
  • Fault Report

Specifications

Nominal voltage range (AC power grid)100 … 240 V~
Frequency50 … 60 Hz
Maximum charging power2 kW (max. current 50 A)
Maximum discharging power400 W (max. current 10 A)
External interfaceUSB 2.0‑Rugged
Operating ambient temperature-20 °C to +55 °C
Storage ambient temperature0 °C to +40 °C
Protection classI

Frequently asked questions

What qualifications are required to operate the VAS 6910?

Operators must be a high‑voltage technician, high‑voltage expert, electrically qualified person for high‑voltage systems, or an electrician for special tasks.

What is the required power‑cord plug for the VAS 6910?

The device uses a C19 plug on the mains cord set for connection to the power source.

What are the maximum charging and discharging powers of the VAS 6910?

The VAS 6910 can charge at up to 2 kW (50 A) and discharge at up to 400 W (10 A).

What safety distance is required when operating near flammable fumes?

The device should be operated at least 460 mm (18 inches) above the floor to keep it away from accumulated flammable fumes.

Download PDF (3.4 MB)