The Present Intelligent Voltage Protector is a product that uses a high response speed microprocessor and has an E2PROM memory that can store the user's most common parameters. It has functions such as undervoltage protection, overvoltage protection, overload protection, connection delay protection, surge and spike protection, etc. It also has an LED digital display that can display the output voltage, the power of the connected equipment, the connection delay and the status of the setting parameters.
This manual covers the TRV SMART 10, SMART 10 PLUS, SMART 20, and SMART 30 intelligent voltage protectors. It describes their protection functions, digital display, adjustable parameters, configuration procedure, and technical characteristics.
The document also includes usage recommendations, a parameter adjustment diagram, a characteristics table, and warranty terms for the product family. This manual is written in Spanish.
| Nominal voltage | 220 V |
|---|---|
| Frequency | 50 Hz |
| Response time (high/low voltage) | 1 s |
| Reconnection hysteresis | 5-10 V |
| Low-voltage cutoff default | 175 V |
| High-voltage cutoff default | 250 V |
| Connection delay default | 6 s |
| Overload cutoff default (SMART 10 / SMART 10 PLUS) | 1500 W |
| Overload cutoff default (SMART 20) | 2400 W |
| Overload cutoff default (SMART 30) | 3200 W |
| Surge protection (SMART 10 / SMART 10 PLUS) | 190 J |
| Surge protection (SMART 20 / SMART 30) | 380 J |
| Peak current (SMART 10 / SMART 10 PLUS) | 4500 kA |
| Peak current (SMART 20 / SMART 30) | 6500 kA |
| Response time to peaks | 10 ns |
| RFI/noise protection | Yes on SMART 20 and SMART 30 only |
| Dimensions | 65 x 132 x 77 mm (SMART 10); 66 x 265 x 56 mm (SMART 10 PLUS); 105 x 160 x 77 mm (SMART 20); 133 x 193 x 58 mm (SMART 30) |
| Weight | 180 g (SMART 10); 470 g (SMART 10 PLUS); 300 g (SMART 20); 500 g (SMART 30) |
The default low-voltage cutoff is 175 V.
The default high-voltage cutoff is 250 V.
The warranty period is 12 months from the sale date shown on the invoice or warranty registration.
The protector exits configuration mode and operates normally.