A reactor vessel internals comprehensive vibration assessment program(RVI CVAP) of an advanced power reactor 1400(APR1400) is being verified on the integrity of RVI for the design life of the plant by performing the non-prototype category-2 type on the US Nuclear Regulatory Commission Guide(NRC RG) 1.20, for which consists of a vibration and stress analysis program, a limited vi- bration measurement program, an inspection program, and the correlation of these programs. The aim of this paper is to describe the plan for the vibration measurement, test and acceptance criteria por- tion, and documentation and results of the APR1400 RVI CVAP.
This paper discusses the comprehensive vibration assessment program (CVAP) for the APR1400 reactor vessel internals (RVI). The program is being verified as a non-prototype category-2 type under US Nuclear Regulatory Commission Guide (NRC RG) 1.20 and includes vibration and stress analysis, a limited vibration measurement program, an inspection program, and correlation of these programs.
The paper focuses on the vibration measurement, test and acceptance criteria portion. It outlines the measurement plan, transducer types and locations, data acquisition requirements, planned data analysis, and sensor requirements such as static pressure, operating temperature, frequency response, and hermetic sealing for RVI applications.
| Static pressure | 158.2 kgf/cm² (2250 psi) |
|---|---|
| Operating temperature | 291.3 °C (556.3 °F) |
| Dynamic strain gage frequency response | 1 to 500 Hz |
| Accelerometer dynamic measuring range | 200 g |
| Dynamic pressure transducer sensitivity | 16 pC/psi (232 pC/bar) or greater |
| Cable outer diameter | 2 mm |
It includes a vibration and stress analysis program, a limited vibration measurement program, a full inspection program, and the correlation of these programs.
CVAP is intended to demonstrate that the RVI is adequately designed to withstand flow-induced vibration forces at normal and transient plant operating conditions for the design life of the plant.
The planned transducers include uniaxial piezoelectric accelerometers and piezoelectric dynamic pressure sensors.
The data are used for comparative analysis to determine whether the measured stress levels are acceptable for long-term plant operation.