Jingdiao 03-X4000 Horizontal Zero-Point Quick-Change Clamping System User Manual

卧式零点快换夹持系统采用加压释放、泄压锁紧的气动工作模式,锁紧状态下,具有一定的自锁能力,能够适用于钻、铣、铰、镗、磨等各种加工工艺。


Jingdiao 03-X4000 Horizontal Zero-Point Quick-Change Clamping System User Manual - cover page
Brand
Jingdiao
Category
Other
Document type
User Manual
Language
Chinese
Pages
10
File format
PDF
File size
2.6 MB
Published
05 November, 2023
Updated
05 November, 2023
MD5 checksum
020DB4F3C84A78375DE16473704440A0

About this manual

The Jingdiao 03-X4000 horizontal zero-point quick-change clamping system is a modular pneumatic workholding system built from a quick-change base, quick-change body, pull studs, angle locators and adapter plates. It releases under air pressure and locks when the pressure is released, has a degree of self-locking when clamped, and is intended for drilling, milling, reaming, boring and grinding on three-, four- and five-axis machine tools, used alone or combined according to workpiece size.

The manual covers the parts list and dimensions of the JD-ZCS-115 quick-change unit (03-1002), the T115 adapter plate system, the A-type pull stud (03-1003), the S1 angle locator (03-1005) and the H90 base (03-4001), together with the 0.5-0.8 MPa air supply requirement, assembly, use and calibration methods, usage precautions, maintenance, troubleshooting and safety measures. This manual is written in Chinese.

What's inside

  • Product Overview
  • Advantages of Zero-Point Quick-Change Technology
  • 03-X4000 Product Features
  • Assembly Diagram and Parts List
  • JD-ZCS-115 Quick-Change Unit
  • T115 Adapter Plate System
  • A-Type Pull Stud (03-1003) and S1 Angle Locator (03-1005)
  • Calibration Method
  • Usage Standards and Precautions
  • Maintenance, Troubleshooting and Safety

Specifications

Repeat center positioning accuracy< 0.003 mm
Service life300,000 cycles
Working air pressure0.5-0.8 MPa
Maximum solid particle diameter in air supply≤ 5 μm
Structure / materialHardened stainless steel, hardness ≥ HRC50
Base H90 dimensionsL 115 mm, D 100 mm, H 90 mm

Frequently asked questions

What air pressure does the zero-point quick-change system need?

It needs an air supply pressure of 0.5-0.8 MPa; if the pressure is too low the quick-change unit may not open and close correctly.

What is the repeat center positioning accuracy of the quick-change unit?

The stated repeat center positioning accuracy is less than 0.003 mm.

How is the mounting angle of the zero-point quick-change calibrated?

Method one uses a dedicated calibration block with an angle error under 10 s, aligned on the straight edge of the block. Method two uses a self-made auxiliary fixture with an angle error under 20 s, calibrated at points A and B.

What should be done if the clamping tongue will not open?

Check the air supply pressure and adjust it to 0.5-0.8 MPa; if the problem remains, return the unit to the factory for repair.

Download PDF (2.6 MB)