About this manual

This is the instruction manual for the Midea MFS90GSS gas/electric cooker. It opens with general warnings for safe use, a list of what to record for easy reference (model, colour, serial number, installation date, dealer), and guidance on ventilation and room requirements. A section for the qualified technician covers clearances to combustible and non-combustible materials, overall dimensions, fitting the splash guard and securing the cooker to the rear wall with the supplied chains.

The manual then describes the gas installation: the inlet manifold extension pipe, the natural gas pressure regulator and test point, hose requirements and leak checking. Gas conversion and adjustment are covered, including changing the injectors and adjusting the minimum flow when converting between natural gas and U-LPG, followed by the burner pressure settings for 5 burner models.

What's inside

  • Getting to know your new cooker
  • Provision for ventilation
  • Positioning and installation
  • Overall dimensions
  • General information
  • Environmental notice
  • When you call for service
  • Clearances to combustible materials
  • Fitting the splash guard
  • Gas connection

Specifications

Adjustable height89/149 mm
Burner pressure, 5 burner models1 kPa for Natural Gas, 2.75 kPa for U-LPG
Minimum clearance above maintop650 mm
Gas hose internal diameter10 mm
Legs4 legs for height alignment with furniture
Gas installation standardAS5601

Frequently asked questions

What burner pressure should the cooker be set to?

On 5 burner models the burner pressure is set to 1 kPa for Natural Gas and 2.75 kPa for U-LPG, with the wok burner operating at full rate.

How much space is needed above the cooker?

Any combustible construction above the cooker must be at least 650 mm above the maintop.

Why must the stabilizing chains be installed?

They are required for safety to prevent accidental tipping of the appliance, for example by a child climbing onto the open oven door.

Can a steam cleaner be used to clean the appliance?

No, the manual states that a steam cleaner is not to be used for cleaning this appliance.