IPU Series Programmable Linear DC Power Supply User Manual introduces the features and specifications of IPU series products.
The IPU series is a modular programmable linear DC power supply from INTERLOCK that can install four power supplies in one 2U/19-inch standard chassis. It uses precision linear regulation for very low noise output, with LED digital displays for voltage and current and an optional display module.
The series provides optional RS232 or RS485 interfaces for remote control and computer networking, includes OVP, OCP, OTP, and fan-fault protection, and is intended for applications such as automation control systems. This manual is written in Chinese.
| Models | IPU5-12SL, IPU10-6SL, IPU20-3SL, IPU30-2SL, IPU48-1.25SL, IPU60-1SL, IPU100-0.6SL, IPU200-0.3SL, IPU300-0.2SL |
|---|---|
| Chassis capacity | 4 units in one 2U/19-inch standard chassis |
| Voltage ripple (5 Hz to 1 MHz, RMS) | 0.5 mV (IPU5-12SL to IPU60-1SL), 1 mV (IPU100-0.6SL), 2 mV (IPU200-0.3SL), 3 mV (IPU300-0.2SL) |
| Voltage line regulation | 0.005% + 1 mV to 0.005% + 5 mV depending on model |
| Voltage load regulation | 0.005% + 2 mV to 0.005% + 5 mV depending on model |
| Transient response time | 50 µs |
| Voltage temperature coefficient | 50 ppm/°C |
| Current ripple (5 Hz to 1 MHz, RMS) | 3, 2, 1, or 0.5 mA depending on model |
| Current line regulation | 0.5 mA |
| Current load regulation | 0.5 mA |
| Current temperature coefficient | 300 |
| Programming interface baud rate | 19200 or 57600 bps |
| Programming interface data format | 8 data bits, 1 stop bit, no parity |
| RS485 address range | 1 to 127 |
| Over-temperature protection | 95°C; shuts off OUTPUT, displays Err, and sounds an alarm |
| Over-voltage protection (OVP) values | 5.5, 11, 22, 33, 52.8, 66, 110, 220, 330 V by model |
| Over-current protection (OCP) values | 13.2, 6.6, 3.3, 2.2, 1.375, 1.1, 0.66, 0.33, 0.22 A by model |
| OVP/OCP trigger pulse width | 50 ms; shuts off OUTPUT, displays Err, and sounds an alarm |
| Fan fault protection | Shuts off OUTPUT, displays Err, and sounds an alarm |
| Short-circuit protection | Internal short-circuit protection circuit |
| Operating environment | 0 to 40°C; 10% to 90% RH |
| Storage environment | -10 to 60°C; below 90% RH |
| Cooling | Fan forced cooling |
| Output polarity | Positive or negative output can be grounded |
| Insulation voltage | ±500 V |
| Warranty | 2 years from shipment |
| Display | LED digital display for voltage and current |
| Display module | Optional voltage and current display module |
| Setting/display resolution | Up to 5 digits for voltage and current |
| Programming interfaces | Optional RS232 or RS485 |
| Ripple and temperature drift | Very low ripple and temperature drift |
| Remote compensation | Available |
| Computer control software | Custom control software |
| Protection | OVP, OCP, OTP, and fan-fault audible/visual alarms |
The IPU series is warranted for two years from the date of shipment.
It activates at 95°C, shuts off OUTPUT, displays Err, and sounds an alarm.
Optional RS232 or RS485 interfaces are available.
The operating range is 0 to 40°C and 10% to 90% RH.