Jingdi Smart Potentiometer Signal Transmitter User Manual

This product can input three-wire potentiometer or linear resistance signals, transmit isolated single or dual linear current/voltage signals, and realize three-way isolation between input, output and power supply.


Jingdi Smart Potentiometer Signal Transmitter User Manual - cover page
Brand
Jingdi
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
2
File format
PDF
File size
235 KB
Published
04 November, 2023
Updated
04 November, 2023
MD5 checksum
147332501DB1C8674AA6F3A42C9CAFA1

About this manual

Jingdi's Smart Potentiometer Signal Transmitter accepts three-wire potentiometer or linear resistance input and provides isolated single- or dual-channel linear current or voltage output. The document describes the transmitter's specifications, output behavior, wiring, dimensions, panel indicators, operating environment, installation, and programming and calibration.

The manual lists potentiometer input ranges such as 0–1 kΩ, 0–4.7 kΩ and 0–10 kΩ, plus linear resistance ranges including 0–400 Ω, 0–1 kΩ, 0–4.7 kΩ and 0–10 kΩ. It also gives output current and voltage options, isolation accuracy, response time, load capability, supply voltage, power consumption, dimensions, and operating temperature. This manual is written in Chinese.

What's inside

  • Performance overview
  • Important technical parameters
  • Output status
  • Wiring diagram
  • Dimensions
  • Panel indicators
  • Operating environment
  • Installation method
  • Programming and calibration
  • Grounding notes

Specifications

Potentiometer input ranges0–1 kΩ, 0–4.7 kΩ, 0–10 kΩ and others
Linear resistance input ranges0–400 Ω, 0–1 kΩ, 0–4.7 kΩ, 0–10 kΩ
Current output0–10 mA, 4–20 mA, 0–20 mA and others
Voltage output0–5 V, 0–10 V, 1–5 V and others
Isolation accuracy±0.2%FS at 25°C ±2°C
Response time≤2 s
Temperature drift<30 ppm/°C
Load capability<350 Ω
DC supply range18–32 Vdc, typical 24 Vdc
Power consumption0.6 W for one output and 0.9 W for two outputs at 24 Vdc
Dimensions22.5 mm x 100 mm x 115 mm (W x H x D)
Operating ambient temperature-20 to +60 °C

Frequently asked questions

What input signals can the transmitter accept?

It accepts three-wire potentiometer or linear resistance signals, with potentiometer ranges such as 0–1 kΩ, 0–4.7 kΩ and 0–10 kΩ.

What is the DC supply range?

The DC supply range is 18–32 Vdc, with 24 Vdc as the typical value.

What does the PWR indicator show?

PWR is a green power indicator that stays on when the instrument is operating normally.

What programming and calibration methods are available?

The manual lists a handheld Chinese programmer, a simple programmer, and computer USB programming with a dedicated adapter and software.

Download PDF (235 KB)