This manual provides important safety information and instructions on how to set up your battery charger. In order to minimize that risk, it’s important to read this manual carefully. Keep this manual in a safe place, review it frequently and ensure that all users have read it to ensure safe operation.
This ROHR operation manual covers the DFC-10P, DFC-50P, DFC-450P and DFC-650P battery chargers. It opens with a quick start guide for connecting the charging leads, selecting output voltage, mode and amperage, and disconnecting the charger safely, then lists the charger's safety features and the functions and controls: voltage selection, amperage selection, pulse repair technology and the charging/jump start mode icons.
The manual gives detailed safety instructions and a technical data table with input and output voltage, charging and starting current, input power and battery capacity for each model. It also describes the panel controls of all four chargers figure by figure, and includes a CE Declaration of Conformity issued for Union Mart Ltd. The same content is repeated in French, German, Italian and Spanish sections.
| DFC-10P input/output voltage, charging current and function | 230 V input; 6/12 V output; 5/8 A charging current; 10 A max charging current; charge only |
|---|---|
| DFC-10P battery capacity | 20-150ah |
| DFC-50P input/output voltage, charging current, starting current and function | 230 V input; 12/24 V output; 20/30 A charging current; 45 A max; 130 A starting current; charge/start |
| DFC-450P input/output voltage, charging current, starting current and function | 230 V input; 12/24 V output; 40/50 A charging current; 70 A max; 300 A starting current; charge/start |
| DFC-650P input/output voltage, charging current, starting current and function | 230 V input; 12/24 V output; 60/70 A charging current; 100 A max; 480 A starting current; charge/start |
| DFC-650P battery capacity | 120- 1000ah |
| Fuses for DFC-650P | 3 x 50 A fuses in the fuse holder |
| Fuses for DFC-450P | 2 x 50 A fuses |
| Maximum jump start duration | 5 seconds, followed by a 20 second cool down time |
Apply a jump start for a maximum of 5 seconds, then allow a 20 second cool down time.
The automatic circuit breaker stops charging in the event of overheating and charging starts again automatically after cooling.
No. The battery must be disconnected from the vehicle before it is connected to the charger, otherwise the vehicle and/or charger electric systems may be damaged.
Insert 3 x 50 A fuses into the fuse holder; a blown fuse must be replaced with an identical fuse.