YOTO DU5 Series Intelligent Current and Voltage Meter User Manual

DU5 series intelligent current and voltage meter is a series of AC and DC voltage and current meters produced by YOTO Electric. The product features are true RMS measurement, high measurement accuracy, up to 0.2% full scale accuracy, and output offset setting to improve the stability of the instrument and system.


YOTO DU5 Series Intelligent Current and Voltage Meter User Manual - cover page
Brand
北崎
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
7
File format
PDF
File size
1.3 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
85E208FF925633342B7ACA2477C5CC42

About this manual

The DU5 Series intelligent current and voltage meter has a 5-digit LED display and true RMS measurement. The manual lists model codes and example ranges for AC and DC current and voltage, along with panel layout, dimensions and cutout size.

The document gives technical parameters, alarm value setting for AL1–AL5, and menu-based settings including LCK, dP, Ft, FH, FL and oL. Optional functions include up to five alarm outputs, RS485 Modbus-RTU communication, and 4–20 mA analog output, with 0–10 V available on request. This manual is written in Chinese.

What's inside

  • Model code explanation
  • Model examples
  • Technical parameters
  • Panel description
  • Dimensions and cutout size
  • Meter operation instructions
  • Alarm value setting
  • Function parameter setting flow
  • Menu parameters (LCK, dP, Ft, FH, FL, oL)

Specifications

Display5-digit LED, true RMS measurement
Measurement accuracy±0.2% FS ±2 digit
Power supplyAC90-260V; DC24V available on request
Relay contact capacity250VAC/3A or 30VAC/5A
Input signal typesAC current, AC voltage, DC current, DC voltage
Display range0.0001 to 99999, any input range
Alarm outputsUp to five alarm channels, alarm values settable
CommunicationRS485, standard Modbus-RTU protocol
Analog output4-20 mA; 0-10 mA / 0-10 V available on request
Sampling speedSettable from 2 to 20 times per second

Frequently asked questions

What power supply does the DU5 Series support?

It supports AC90-260V; DC24V is available as an option.

What is the measurement accuracy of the DU5 Series?

The stated accuracy is 0.2% FS ±2 digit.

How many alarm outputs can the meter have?

Up to five alarm channels are available, and the alarm values can be set.

What communication protocol does the optional RS485 interface use?

The manual specifies standard Modbus-RTU communication.

Download PDF (1.3 MB)