Lifengjie 104LPVDF Liquid Level Switch Instruction Manual

The instruction manual of 104LPVDF liquid level switch introduces the product's basic parameters, installation and use, contact protection circuit, wiring and contact instructions, common faults and elimination.


Lifengjie 104LPVDF Liquid Level Switch Instruction Manual - cover page
Brand
Lifengjie
Category
Buoyancy level switch
Document type
User Manual
Language
Chinese
Pages
2
File format
PDF
File size
212 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
BE23619539C5648F98EB2931F37F44DA

About this manual

This is the Chinese instruction manual for the Lifengjie (Qingdao Lifengjie Electronic Technology Co., Ltd.) model 104LPVDF liquid level switch, a float-type switch with a reed switch element sealed in a tube and a PVDF body. The marked basic parameters include 50W contact capacity, 220Vdc/0.5A electrical range, 1/2NPT connection, ON/OFF output, working pressure below 0.3 MPa, medium specific gravity above 0.8 g/cm2 and horizontal mounting.

The manual gives handling and receiving precautions, installation instructions, contact protection circuits for inductive and capacitive loads, wiring and contact notes, and a table of common faults with causes and remedies. It also lists a technical contact number for problems that cannot be solved. This manual is written in Chinese.

What's inside

  • 基本参数
  • 收货与检查
  • 安装使用
  • 接点保护电路
  • 配线及接点说明
  • 常见故障及排除

Specifications

Contact capacity50W
Electrical range220Vdc/0.5A
Connection1/2NPT
Insulation resistance> 100 MΩ
Output signalON/OFF
Working pressure< 0.3 MPa
Medium specific gravity> 0.8 g/cm2
MaterialPVDF
Mounting methodHorizontal

Frequently asked questions

What should be checked when the switch gives no signal?

Check the liquid specific gravity, the mounting position and whether the voltage and current exceed the rating, and confirm that the magnet and switch positions correspond.

What must be avoided when installing the switch?

Do not wrap too much sealing tape on the thread and do not use excessive force with the wrench, as this can crush the reed switch glass tube inside the stem.

Can the switch directly start and stop a pump?

No. It is a low-power contact switch and cannot directly control a pump; connect an intermediate relay or solenoid valve instead.

What is advised for capacitive or high-power loads?

Add a protection circuit such as an RC snubber, varistor, diode, current-limiting resistor or filter across the load or across the switch contacts.

Download PDF (212 KB)