This is the user manual of the rail-mounted installation electric energy meter. It introduces the model, function, selection, measurement, metering, demand, event record, communication function, energy pulse, installation and wiring, operation and setting of the product.
Applicable models are DDS1946, DDSF1946, DSS1946, DSSF1946, DTS1946, DTSF1946 and v3004. The manual covers standards, product overview, selection, technical specifications, features, installation and wiring, operation, settings, and Modbus-RTU communication, including single-phase and three-phase communication address tables.
The meters measure parameters such as voltage, current, power, power factor, frequency, and demand. They support bidirectional and time-of-use energy metering, event records, RS485 Modbus-RTU communication, and energy pulse output. This manual is written in Chinese.
| Accuracy class | Direct access: active energy class 1 or 0.5S; via CT: active energy class 0.5S |
|---|---|
| Rated voltage | 220V; 3×380V; 3×220/380V |
| Input current | Direct access 5(100)A; via CT 1.5(6)A; three-phase 3×5(100)A / 3×1.5(6)A |
| Frequency | 50/60 Hz |
| Working voltage range | 0.8Un to 1.2Un |
| Power consumption | Voltage circuit <5VA; current circuit <2VA |
| Starting current | Direct access 0.004 Ib / 0.001In; via CT 0.002 In / 0.001In |
| Energy pulse output | 1 active energy pulse output, optocoupler open-collector, pulse width (80±20%) ms |
| Clock error | ≤0.5 s/day |
| Communication | RS485, Modbus-RTU, baud rate up to 9600 bps |
| Dimensions | Single-phase 72×90×63.5 mm; three-phase 126×90×63.5 mm |
| IP protection | IP51 (panel) / IP20 (housing) |
| Operating temperature | (-10 to 55) °C |
| Storage temperature | (-25 to 70) °C |
| Relative humidity | (5 to 95)%, no condensation |
It uses an RS485 interface with the Modbus-RTU protocol at up to 9600 bps.
Direct access supports active energy class 1 or 0.5S; via CT supports active energy class 0.5S.
The operating temperature range is (-10 to 55) °C.
The meter supports 2 sets, each with 12 periods and 4 rates.