DL8 electrical parameter measurement instrument operation manual, provides instrument model, range, communication, output function, pressure resistance, insulation resistance, working environment, sampling speed, external dimensions and other parameter information
This document serves as the operation manual for the DL8 Series digital current and voltage meter. It details the main technical parameters, including power supply requirements, measurement accuracy, and output capabilities. The manual also describes the instrument's model naming conventions and specific input/output ranges for various configurations. This manual is written in Chinese.
| Communication Interface | Standard RS485, Modbus RTU |
|---|---|
| Dimensions | 96W*48H*100L |
Yes, it features a standard RS485 communication interface using the Modbus RTU protocol.
AC/DC 85–265 V at 50/60 Hz, or DC 24 V (custom).
±0.5% F.S ±2 digits for AC frequencies within 100 Hz.
4–20 mA, with load capacity ≤600 Ω and accuracy ±0.5% F.S.