Hichance HC-GY61T Integrated Rebar Scanner User Manual

HC-GY61T Integrated Rebar Scanner is a portable intelligent non-destructive testing device, which is used to detect steel-concrete structure construction quality, can detect steel-protection layer thickness, rebar position, direction and distribution, and can detect magnetic and conductive bodies in non-magnetic and non-conductive media.


Hichance HC-GY61T Integrated Rebar Scanner User Manual - cover page
Brand
Hichance
Category
detectors
Document type
User Manual
Language
Chinese
Pages
18
File format
PDF
File size
1.9 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
07921AD36D43CFE7B255EFFDDE995522

About this manual

The HC-GY61T is a portable intelligent non-destructive testing device for checking the construction quality of reinforced concrete structures. It measures rebar protective layer thickness and rebar position, direction, and distribution, and can also detect magnetic and conductive objects in non-magnetic and non-conductive media.

The manual explains the instrument's components, keys and charging, then walks through thickness detection, diameter estimation, waveform scanning, JGJ detection, grid detection, profile detection, data browsing and deletion, calibration and system settings. It also covers installation and use of the PC data analysis software for reading files and generating reports. This manual is written in Chinese.

What's inside

  • Overview
  • Instrument Operation
  • Thickness Detection
  • Diameter Estimation
  • Waveform Scanning
  • JGJ Detection
  • Grid Detection
  • Profile Detection
  • Instrument Calibration
  • PC Data Analysis Software

Specifications

Display2.8-inch high-resolution color LCD, 320 x 240 pixels
Storage capacity500 components or 100,000 measurement points
Battery operating timeApprox. 24 hours on a full charge
Operating temperature-10 °C to 40 °C
Operating relative humidityBelow 90% RH
Storage temperature-20 °C to 50 °C
Maximum waveform scan distance5.2 m (5200 mm)
Data interfaceUSB for computer connection, data transfer and charging; SENSER reserved port

Frequently asked questions

What is the operating temperature range of the HC-GY61T?

The manual states an ambient temperature range of -10 °C to 40 °C, with relative humidity below 90% RH.

How long can the instrument operate after a full charge?

It can operate continuously for about 24 hours after the battery is fully charged.

What is the maximum distance for waveform scanning?

Waveform scanning has a maximum distance of 5.2 m (5200 mm). If this distance is exceeded, the instrument gives a continuous buzzer alert.

How can I tell when charging is complete?

The red indicator above the instrument stays on while charging and turns off when charging is complete.