CT6840 temperature controller user manual, the main functions include temperature display, temperature control, compressor start delay protection, temperature probe failure can be operated according to the set on-off ratio regularly, two kinds of defrosting mode, three kinds of defrosting start mode, two kinds of defrosting end mode, defrosting drip, manual defrosting, seven kinds of fan operation mode, high and low temperature alarm, sensor abnormality alarm, one external alarm signal input, password password, real time clock, Fahrenheit centigrade conversion
The Chuangtai CT6840 is a temperature controller with temperature display and control, supporting cooling or heating modes. It includes compressor startup delay protection, temperature sensor fault handling, two defrost modes, three defrost start modes, seven fan operation modes, high and low temperature alarms, sensor abnormality alarms, external alarm input, password protection, real-time clock, and Fahrenheit/Celsius conversion.
The manual provides technical specifications, panel indicator light meanings, digital tube display codes, operating procedures for temperature and clock settings, forced cooling or heating, manual defrost, advanced parameter configuration, and basic working principles for temperature control and alarms. This manual is written in Chinese.
| Temperature range | -50~150℃ / -58~302℉ |
|---|---|
| Power voltage | 220V±10% or 380V±10% |
| Operating environment | -30℃~80℃, humidity ≤85% |
| Output contact capacity | 8A/250VAC (pure resistive load) |
| Temperature sensor | NTC R25=5kΩ, B(25/50)=3470K |
It measures -50~150℃ or -58~302℉ with 0.1 resolution.
Long press the S key for 2 seconds to enter temperature setting state, then use the up or down keys to change the value.
It indicates the trial period has ended and the controller cannot work.
8A/250VAC for a pure resistive load.