This manual introduces the basic functions, usage methods, and installation precautions of the ZL series general air conditioner wall-mounted control board.
This manual covers the ZL Series universal wall-mounted air conditioner control boards manufactured by Suzhou Lily Technology Co., Ltd. The series is intended for repair and modification of wall-mounted air conditioners (excluding inverter models), with models from ZL-U02A through ZL-U05AM-H covering both cooling-only and cooling-heating types.
The document describes operating modes (auto, cooling, dehumidification, ventilation, heating), technical specifications, display panel operation, wiring diagrams, and installation instructions for stepper motors, tap-speed indoor fans, and PG-type indoor fans. It also explains auxiliary heating and power-off memory functions on selected models. This manual is written in Chinese.
| Power Supply | AC 185-245V/50Hz |
|---|---|
| Operating Temperature | -10 to +45°C |
| Humidity | 5%-95%RH (non-condensing) |
| Temperature Sensor | NTC R(25°C)=10K±3%, B(25/50°C)=3470 |
| Temperature Setting Range | 15-30°C |
| Self Power Consumption | <4W |
| Indoor Fan Output | 3A (220V/50Hz relay) |
| Outdoor Fan Output | 3A (220V/50Hz relay) |
| Compressor Output | 15A (220V/50Hz relay) |
| Auxiliary Heating Output | 15A (220V/50Hz relay) |
The ZL series control board is designed for repair and modification of wall-mounted air conditioners, excluding inverter models.
The control board operates on AC 185-245V/50Hz.
The yellow indicator light flashes and the compressor and indoor fan stop working, putting the control board into shutdown protection mode.