Dayang Chuangan DY-6001 Dynamometer Controller User Manual

DY-6001 dynamometer controller user manual, introduces the overview, main functions and features, technical indicators, shell size and hole size, appearance introduction, instrument operation instructions, parameter description, automatic control mode diagram, parameter table, serial port communication instructions, dynamometer interface instructions, excitation output interface instructions, motor control interface instructions, current output instructions, dynamometer torque calibration instructions, equipment connection instructions and packing list.


Dayang Chuangan DY-6001 Dynamometer Controller User Manual - cover page
Brand
大洋传感
Category
Automation control Equipment
Document type
User Manual
Language
Chinese
Pages
12
File format
PDF
File size
1.3 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
CDB13B7AD7026E662DC55F6EFC8C213C

About this manual

The DY-6001 dynamometer controller samples torque sensor and dynamometer signals, controls a magnetic powder or hysteresis brake, and sends the data to a host computer. It processes torque and speed inputs, calculates output power, and displays torque, speed, and power values.

The manual covers main functions and features, technical specifications, housing and cutout dimensions, front-panel appearance, instrument operation, parameter descriptions, the automatic control mode diagram, the parameter table, serial communication, dynamometer interface, excitation output, motor control interface, current output, torque calibration, device connection, and packing list. Operation modes include manual, single-stage automatic, multi-stage automatic, host-computer, and reset, with PID parameter tuning. This manual is written in Chinese.

What's inside

  • Main Functions and Features
  • Technical Specifications
  • Housing and Cutout Dimensions
  • Appearance and Front Panel
  • Instrument Operation
  • Parameter Descriptions
  • Automatic Control Mode Diagram
  • Parameter Table
  • Serial Communication
  • Dynamometer Interface

Specifications

Torque rangeFreely settable, maximum 99999
Torque display range-9999 to 99999
Speed display range0 to 99999
Supported speed sensor signals60, 120, 1250, 1500, 2000 pulses/rev
Maximum torque sampling rate800 times per second
Maximum speed sampling rate20 times per second
Power supplyAC220V ±10%, 50/60 Hz
Power consumption<90 VA
Operating environmentTemperature -20 to 50 °C; relative humidity ≤85% RH
Current output0 to 2000 mA; maximum voltage 30 V; current accuracy ±2 mA
Serial communicationRS232-based Modbus RTU, DB9 interface
Baud rate19200

Frequently asked questions

What is the maximum torque sampling rate?

The controller can sample torque up to 800 times per second.

Which speed sensor pulse options does the manual list?

It lists 60, 120, 1250, 1500, and 2000 pulses per revolution.

How do you open the parameter menu?

Long-press the K1 key to enter the menu interface.

How can motor and brake power be cut quickly in an emergency?

Press the K5 reset key to cut motor power and brake power immediately.