Jomard LFD-1006 LFD-1510 Multifunctional Secondary Lifting Hoist Installation and Use Manual

Jomard is a set of equipment consisting of two lifting points and a power automatic winch at both ends. It is mainly used for the secondary lifting of electric projection screens in hotel banquet halls, as well as for the lifting and lowering of activity banners and banners in high-ceiling scenes. The product is small in size, short in height, light in weight, and driven by a dual-core motor with dual-belt linkage. It has low noise, strong power, reliable braking, and a double flexible traction structure provides double safety protection. The adaptive synchronization patent technology ensures that multiple devices remain in a state of synchronous operation at a uniform speed when they are coupled. The structure is compact and takes up little space, making it extremely suitable for use in hotel banquet halls with a dense network of air conditioning, fire protection, and electrical pipes in the ceiling.


Jomard LFD-1006 LFD-1510 Multifunctional Secondary Lifting Hoist Installation and Use Manual - cover page
Brand
Jomard
Category
Other
Document type
Installation Guide
Language
Chinese
Pages
14
File format
PDF
File size
2.3 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
56D649B342045C0DC650D4B0EBB819EB

About this manual

The Jomard LFD-1006/LFD-1510 is described as a multifunctional secondary lifting hoist set made up of two lifting hoists and one automatic power cable reel. The manual states that it is mainly used for secondary lifting of electric projection screens in hotel banquet halls and for lifting movable slogans and banners in high-ceiling areas.

The manual says it is written for dealers and installation technicians, and that customers should not install the product themselves but should hire qualified technicians. It covers important safety instructions, product introduction, parts list, specifications, installation environment, installation steps for ceilings that are not yet installed or already installed, ceiling panel openings, and power-on adjustment of the upper limit. This manual is written in Chinese.

What's inside

  • Important Safety Instructions
  • Product Introduction
  • Parts List
  • Specifications
  • Installation Environment
  • Installation Steps
  • Scheme 1: Decorative Ceiling Not Installed
  • Scheme 2: Decorative Ceiling Already Installed
  • Ceiling Decoration Panel Opening
  • Power-On Adjustment and Upper Limit Setting

Specifications

Dimensions (single hoist)LFD-1006: W380 x D230 x H300 mm; LFD-1510: W350 x D225 x H380 mm
Load capacityLFD-1006: ≤200 kg per set (100 kg per unit); LFD-1510: ≤300 kg per set (150 kg per unit)
Net weightLFD-1006: 10 kg per unit; LFD-1510: 20 kg per unit
Travel lengthLFD-1006: ≤6 m; LFD-1510: ≤10 m
Power consumptionLFD-1006: 320 W per set (160 W per unit); LFD-1510: 480 W per set (240 W per unit)
Average running speed800 mm/min for both models
Installation methodThreaded-rod suspension or ceiling-mounted installation
Control methodRS485 weak-current control
Ceiling openingφ150 mm
Hoisting hole spacingW320 x D160 mm
Required installation space heightLFD-1006: >400 mm; LFD-1510: >480 mm

Frequently asked questions

What load can each model lift?

The LFD-1006 set is rated at ≤200 kg (100 kg per unit), and the LFD-1510 set at ≤300 kg (150 kg per unit).

What is included in each LFD-1006/1510 group?

Each group contains two secondary lifting hoists and one power cable reel.

How is the lifting hoist controlled?

The specifications list RS485 weak-current control for the lifting hoist.

What installation space height is required?

The LFD-1006 requires more than 400 mm and the LFD-1510 requires more than 480 mm.