Operation of the vibrator
This user manual covers operation of B and SH vibratory hammers and their power packs. It describes control panel and remote-control operation, power pack start-up checks, emergency-stop testing and reset, and positioning the hammer on a pile with the clamp.
Instructions also cover the rotary-head vibratory hammer, required clamp pressure, clamp wear checks, and the separate mechanical safety chain for B and SH hammers. Warnings address keeping people outside the work area, not using the hammer as a lifting device, and stopping operation if hoses are damaged. This manual is written in Chinese.
| Clamping pressure | 320 bar |
|---|
The clamp must reach a pressure of 320 bar.
Turn the switch clockwise to reset it.
The locking system must be released at least every 30 minutes by fully opening the clamp and needle valve.
A separate mechanical safety chain or wire rope, independent of the vibratory hammer and clamp, must connect the pile to the hammer.