This manual introduces the application method of epoxy robaru cold galvanized paint.
This document is the construction instruction sheet for Luobalu epoxy cold galvanized paint, a zinc-rich coating containing 96% zinc powder. It covers suitable surfaces, coating amounts, film thickness, surface preparation, and application by brush, roller, or spray.
It also sets construction conditions, inspection points, dilution limits, coating intervals, and surface treatment grades for steel and hot-dip galvanized surfaces. The instructions require surface preparation to be completed within two hours before coating and specify minimum average coating thickness. This manual is written in Chinese.
| Zinc powder content | 96% |
|---|---|
| Theoretical coating amount (first coat) | 250 g/m2 |
| Dry film thickness (first coat) | 40 μm |
| Maximum dilution | 5% by weight |
| Surface treatment (steel, sandblasting) | ISO 8501 Sa2 1/2, Rz 20-50 μm |
It is used for corrosion protection of steel components, coating of hot-dip galvanized surfaces, and repair of hot-dip galvanized welded areas.
The average thickness must exceed 85 micrometers in the selected test area.
The coating interval must be at least 24 hours.
Coating should not be applied when the temperature is below 5°C or humidity is above 85%.