This manual provides information on the operation and maintenance of your KEITH® V-FLOOR® DX unloading system, including troubleshooting tips and detailed views of the system parts.
The KEITH V-FLOOR DX is a trailer unloading system that uses KEITH RUNNING FLOOR II technology. This owners manual provides original instructions for operating and maintaining the unloader, including safety information, loading and unloading steps, and a start-up checklist.
It also describes the hydraulic wet kit requirements, troubleshooting and adjustment procedures for valves and cylinders, preventive maintenance, and detailed component views and parts lists.
| Maximum hydraulic oil temperature | 70 °C or 140 °F |
|---|
Open the trailer door, pull the control valve handle all the way out, make sure the ball valve is in the closed (run) position, and engage the P.T.O. at the predetermined unloading RPM.
Switch the ball valve to the open (stop) position.
The maximum oil temperature is 70 °C or 140 °F.
Disengage the trailer from the P.T.O. hydraulic power unit and shut off the power supply before going underneath the trailer.