This document is the BRON V65 vibratory plow operator's manual, which introduces the installation, operation and maintenance of the vibratory plow.
The BRON V65 operator's manual from RWF Industries provides pre-operation checks and operating procedures for BRON vibratory plows. It notes that some items and procedures may not apply to the purchased plow package or the tractor it is mounted on.
The document covers installation to the tractor, warnings, a torque chart, valve-section operation, lubrication points, and the BRON V65 plow warranty. It also warns that applying more than 38,000 lbs drawbar pull voids the warranty and states that hydraulic line pressure must not exceed 2500 PSI.
| Maximum hydraulic line pressure | 2500 PSI |
|---|---|
| Maximum drawbar pull before warranty void | 38,000 lbs |
| Shank and linkage material | Heat-treated alloy steel |
The line pressure must not exceed 2500 PSI, and the relief setting should be adjusted to obtain a 2500 PSI reading.
Applying drawbar pull of more than 38,000 lbs to the V65 plow will void the warranty.
The base warranty is 6 months or 600 operating hours, whichever occurs first, starting from delivery to the first user.
Lubricate all points as per the lubrication guide before any movement of the plow functions.