Lippert Components CCD-0002366 Hydraulic Leveling System Owner's Manual

This document is about the hydraulic leveling system manual. The system consists of four points of contact using either steel or aluminum jacks and a three-valve manifold system. A 12V DC electric motor drives a hydraulic pump that moves fluid through a system of hoses, fittings and jacks to level and stabilize the coach.


Lippert Components CCD-0002366 Hydraulic Leveling System Owner's Manual - cover page
Brand
Lippert Components
Category
Vehicle Accessories
Document type
User Manual
Language
English
Pages
18
File format
PDF
File size
4.7 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
847FB854778317224B70F2D94B4278BE

About this manual

This owner's manual from Lippert Components covers the CCD-0002366 four-point three-valve hydraulic leveling system with an LCD touchpad. It describes a hydraulic system with four points of contact using steel or aluminum jacks and a three-valve manifold, driven by a 12V DC motor that moves fluid through hoses, fittings, and jacks.

The manual includes safety notes, operation, automatic and manual leveling procedures, jack retract procedures, troubleshooting, maintenance, and wiring and plumbing diagrams. It states that the system is primed and tested at the factory but shipped dry, and that this manual replaces earlier LCI manuals.

What's inside

  • Introduction
  • Component Description
  • Safety
  • Operation
  • Automatic Leveling Descriptive Logic
  • Automatic Leveling Procedure
  • Manual Leveling Procedure
  • Troubleshooting
  • Maintenance
  • Wiring Diagram

Specifications

Motor Voltage12V DC
Automatic Leveling Minimum Voltage12.75V DC
Manual Leveling Minimum Voltage9.5V DC
Excess Slope Threshold3.5 degrees

Frequently asked questions

What voltage does the coach require for automatic leveling?

The coach requires 12.75V DC to commence auto-leveling. The manual recommends idling the engine to maintain the minimum required voltage.

What happens if the coach is parked on an excessive slope?

The "EXCESS ANGLE" will appear on the LCD screen if the coach is 3.5 degrees out of level. The coach should then be moved to a more level surface before leveling.

What is required for manual leveling?

Manual leveling requires a minimum of 9.5V DC. The coach should be leveled front-to-rear first and then side-to-side.