This document is a user manual of TT-MTM Wall Controller
The TT-MTM wall controller is a custom-designed controller for HEATSTRIP heaters. It provides heat output control at High, Medium and Low settings and a countdown timer with 1, 2 or 4 hour settings or constant operation. The controller is rated at 15 A and 240 V and needs a minimum load of 250 W before it starts working. One controller can control multiple heaters when the additional units are connected through a contactor or relay.
The manual covers operation, thermal cutout protection, warm-up mode, safety and maintenance. It also includes an installation guide with vent and spacer notes, heater wiring schematic diagrams, diagrams for relay-connected heaters, and warranty terms for Australia and New Zealand.
| Model | TT-MTM |
|---|---|
| Maximum voltage | 240 V |
| Maximum current | 15 A |
| Packaged dimensions | 140 x 90 x 60 mm |
| Weight | 0.5 kg |
| Minimum load | 250 W |
| Heat output settings | High, Medium and Low |
| Timer settings | 1, 2 or 4 hours, or constantly on |
The timer can be set to 1 hour, 2 hours, 4 hours or constantly on.
Direct wiring allows one heater unit, unless the heaters are two THH1500A units.
A thermal cutout switch cuts all power until the controller cools down, after which it continues working as usual.
Do not use water or a damp cloth to clean the controller; dusting is recommended to keep the surface clean.