This is an instruction manual for IMER generators, which covers operation and maintenance of the generators.
The manual covers four IMER generator models: MASTER 6010 DXL15 YN DE, TRISTAR 6510 DXL15 YN DE, MIXTE 5000 DXL15 YN DE, and ARC 180 DXL15 YN DE. It includes safety precautions, specifications, pre‑operation checks, operating procedures, stopping instructions, oil sensor information, wattage guidance, maintenance schedules, step‑by‑step maintenance tasks, storage preparation, troubleshooting, electrical diagrams, and a declaration of conformity.
All models share a Yanmar L100 diesel engine, air‑cooled, with electric starting and a 15‑liter fuel tank. The document emphasizes safe operation, proper grounding, ventilation, and regular maintenance to ensure reliable performance.
| Maximum power LTP (400V 3‑phase) | 5.2 kW (MASTER 6010), 4.7 kW (TRISTAR 6510) |
|---|---|
| Continuous power COP | 4.5 kW (MASTER 6010, TRISTAR 6510, MIXTE 5000), 4.1 kW (ARC 180) |
| Alternator type | Ringless (MASTER 6010, MIXTE 5000), Brushless with ring and brushes (TRISTAR 6510, ARC 180) |
| Engine model | YANMAR L100 |
| Engine type | Diesel, 1‑cylinder, air‑cooled |
| Maximum engine output | 9.3 HP at 3600 rpm |
| Fuel tank capacity | 15 Liters |
| Recommended engine oil | SAE 10W‑30, API class SE or higher |
| Dry weight | 95.5 kg (MASTER 6010), 120 kg (TRISTAR 6510), 109 kg (MIXTE 5000), 115 kg (ARC 180) |
The fuel tank capacity is 15 liters for all four models.
SAE 10W‑30, API class SE or higher is recommended for all‑temperature use.
The MASTER 6010 delivers a maximum power LTP of 5.2 kW at 400V three‑phase.