ISC Systems 328 ICEGARD VERDE Air Conditioning Service Equipment Instruction and Maintenance Manual

This manual is the user and maintenance manual for the 328 ICEGARD VERDE automatic maintenance equipment


ISC Systems 328 ICEGARD VERDE Air Conditioning Service Equipment Instruction and Maintenance Manual - cover page
Brand
ISC Systems
Category
Vehicle maintenance
Document type
User Manual
Language
English
Pages
55
File format
PDF
File size
5.5 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
30F734BA875FF5064FB17B43EF80E9A2

About this manual

The ISC Systems 328 ICEGARD VERDE is an automatic unit intended solely for automobile air-conditioning system maintenance. According to the manual, it can carry out recovery, recycling, vacuum, oil injection, UV injection, system filling, flushing and leak testing with nitrogen, and it is listed for R134a or R1234yf refrigerant as verified on the identification plate.

This instruction and maintenance manual covers the unit description, safety, use, messages, operating description, programs, start of programmed cycles, other menus, additional functions, long-period stop, maintenance and disposal. Technical characteristics include a 12.4 L internal container, 10 Kg maximum storable refrigerant, 9cc compressor, 4.2m3/h vacuum pump, 1200x697x562 mm dimensions, 95 Kg weight and 230 V 50/60 Hz 770 W supply.

What's inside

  • Description of the unit
  • Safety
  • Use
  • Messages
  • Operating description
  • Programs
  • Start of programmed cycles
  • Other menus
  • Additional functions
  • Maintenance

Specifications

RefrigerantR134a or R1234yf
Internal container capacity12.4 L
Maximum refrigerant storable quantity10 Kg
Compressor cubic capacity9cc
Vacuum pump4.2m3/h, 2.5 CFM, 70 l/min
Dimensions1200x697x562 mm
Weight95 Kg
Supply voltage230 V 50/60 Hz
Power770 W
Noise level53.5 dB (A)

Frequently asked questions

What refrigerant can the 328 ICEGARD VERDE use?

The manual lists R134a or R1234yf and says to verify the refrigerant on the identification plate.

What operations can the unit perform?

It can perform recovery, recycling, vacuum, oil injection, UV injection, system filling, flushing and a leak test with nitrogen.

What is the internal container capacity?

The ICEGARD VERDE internal container capacity is 12.4 L.

What is the supply voltage?

The unit is supplied at 230 V 50/60 Hz.