About this manual

This instruction manual covers the FALL SAFE FS701 and FS-LDV-029 anchor points under EN795 - A and Regulation (EU) 2016/425. It presents nomenclature and field of application, donning and setup, and installation details including drill hole diameter, embedment depth, thread size and installation torque.

The document also includes additional information, marking and labels, an equipment record, identification and marking details, and a periodic examination and repair history. It is a multilingual manual with the English instruction section starting on page 4.

What's inside

  • Nomenclature / field of application
  • Donning and setup
  • Installation details
  • Additional information
  • Marking / labels
  • Equipment record
  • Periodic examination and repair history
  • Identification / marking

Specifications

Drill hole diameter14 mm
Nominal embedment depth> 60 mm / < 150 mm
Thread sizeM12
Temperature range-40 °C to +80 °C

Frequently asked questions

What standard does the FS701 anchor point meet?

It is listed as an EN795 - A anchor point.

What drill hole diameter is required?

The drill hole diameter is 14 mm.

What temperature range is listed?

The manual lists -40 °C to +80 °C.