This manual describes the installation, function, operation and maintenance of the solar charge controller SMC-20.
This manual provides detailed instructions for installing, operating, and maintaining the Samlex America SMC-20 solar charge controller. It includes safety warnings, step-by-step installation procedures, LED status explanations, and technical specifications. The controller is designed to manage charging and discharging of lead-acid batteries in solar power systems. It features deep discharge protection and multiple charge modes, with voltage thresholds based on battery state of charge. Proper installation and adherence to safety guidelines are emphasized to prevent fire, explosion, or electric shock risks.
| Maximum Module Input Short Circuit Current at 50°C | 20A |
|---|---|
| Maximum Load Output Current at 50°C | 20A |
| Terminal Size | 16/25 mm² = 6/4 AWG |
| Weight | 345 g .76 LB. |
| Dimensions | 187 x 96 x 45 mm (7.36 x 3.75 x 1.77 inches) |
| Enclosure Protection Class | IP 32 |
| System Voltage | 12V / 24V |
| Ambient Temperature | -25°C to +50°C / -13°F to +122°F |
| Maximum Voltage of Solar Module | 47 V DC |
| Temperature Compensation | -4 mV / °K / Cell |
| Deep Discharge Warning (SOC / LVW) | < 40% / 11.7V ~ 12.3V (12V) / < 40% / 23.4V ~ 24.6V (24V) |
| Deep Discharge Protection (SOC / LVD) | < 30% / 11.2V ~ 11.6V (12V) / < 30% / 22.1V ~ 23.2V (24V) |
| Reconnection Set Point (SOC / LVR) | < 50% / 12.4V ~ 12.7V (12V) / < 50% / 24.8V ~ 25.4V (24V) |
| End of Charge Voltage (Float) | 13.9V (12V) / 27.8V (24V) |
| Boost Charge Voltage (Boost) | 14.4V (12V) / 28.8V (24V) |
| Equalisation Charge Voltage (Equal) | 14.7V (12V) / 29.4V (24V) |
The maximum module input short circuit current at 50°C is 20A.
The maximum load output current at 50°C is 20A.
Deep discharge protection activates at < 30% SOC, with thresholds of 11.2V–11.6V for 12V systems and 22.1V–23.2V for 24V systems.
The end of charge voltage (float) for a 12V system is 13.9V.