This is a manual that guides users on how to assemble Franklin STS series turbine pumps
This Spanish-language assembly manual (Manual de Ensamble) covers Franklin STS series submersible turbine pumps in 5, 6, 8 and 9 inch sizes. It lists the hand tools and equipment required, including the assembly fixture kit (part no. 305386901), and walks through the assembly sequence from shaft inspection and sand collar installation to bowl stacking, discharge assembly, motor coupling and cable guard installation.
The manual gives torque values for bowl bolts, sand collar screws, motor coupling screws and cable guard screws for each pump size, up-thrust spacer thicknesses, and the maximum permitted shaft runout. The final pages contain drawings of the special assembly fixture kit and its mounting plates. This manual is written in Spanish.
| Shaft runout limit | Total indicated runout (TIR) must not exceed 0.002 in when the shaft is supported at each end |
|---|---|
| Sand collar set screw torque | 100-120 lb-in |
| 5 in STS bowl bolt torque | 10-12 lb-ft; 12 bolts on all stages |
| 6 in STS bowl bolt torque | 10-12 lb-ft; 8 bolts on stages 1-9, 14 bolts from the top of stage 9 upward |
| 8 in STS bowl bolt torque | 17-20 lb-ft; 8 bolts on stages 1-12, 16 bolts from stage 13 upward |
| 9 in STS bowl bolt torque | 17-20 lb-ft; 16 bolts on all stages |
| Motor coupling set screw torque | 50-60 lb-in for 5x6, 6x6, 8x6 and 9x6; 100-120 lb-in for 8x8, 9x8 and 9x10 |
| Up-thrust spacer thickness | 0.221 in for 5 in and 6 in STS; 0.250 in for 8 in and 9 in STS |
| Cable guard screw torque | 20-23 lb-in |
| Assembly fixture kit | Part no. 305386901; includes 5, 6, 8 and 9 in assembly fixtures, 8x6 and 9x6 mounting plate, plate screws and shaft bolts |
Basic hand tools plus the assembly fixture kit (part no. 305386901), sleeve hammers, Allen wrenches, a ball-peen hammer, Dow Corning 111 lubricant and Loctite 243.
The total indicated runout (TIR) must not exceed 0.002 in when the shaft is supported at each end; shafts must be straightened mechanically without using heat.
50-60 lb-in for 5x6, 6x6, 8x6 and 9x6 configurations; 100-120 lb-in for 8x8, 9x8 and 9x10 configurations.