This document is the user manual of PTV30 Smart Radiator Controller, which introduces the features and usage of the device.
This user manual covers the Poersmart PTV30 smart radiator controller, a device with a built-in temperature and humidity sensor and a micro motor that opens and closes a radiator angle valve to keep the room at a constant temperature. The controller communicates over RF with the separately sold smart gateway PTG10 and can be operated from a phone app, so home temperature can be set anywhere. The manual also notes that the product does not heat the room itself and fits standard angle valves with an M30X1.5mm connector.
The document walks through installation on the angle valve, boot and shutdown, disassembly, and both automatic (app) and manual RF pairing with the gateway. It then explains operation with the four touch keys and LCD screen: clock setting, auto-mode program setting with the factory preset schedules, override, manual, holiday, ECO and OFF modes, child lock, MAC ID display and the users' option table. A product specification section is listed in the contents.
| Angle valve connector | M30X1.5mm |
|---|---|
| Default frost protection temperature | 7 °C |
| Default energy-saving temperature (ECO) | 9 °C |
| Devices per gateway | 10 devices |
| Pairing distance check | less than 5 meters |
| Valve protection interval | 24 hours |
No. The product has no heating function; if the room does not reach the set temperature, raise the heat medium temperature or check the heating system.
It fits standard angle valves with an M30X1.5mm connector, though some specific models may need an adaptor.
Hold the gateway button until its LED is blinking slowly, then send the pairing command from the radiator controller.
Check that the gateway PTG10 is in pairing mode and that the distance between the controller and the gateway is less than 5 meters, then keep sending the pairing command.