This manual is for installation, operation and maintenance of SKM multistage centrifugal pumps. It covers pump description, applications, pump designation, pump nameplate, technical data, etc.
The Standart Pompa SKM series consists of horizontal ring section multistage centrifugal pumps with closed impellers and diffusers. The manual lists applications including general and municipal water supply, pressurized water supply and booster systems, boiler feed water and condensate, heating and air conditioning, irrigation and sprinkler systems, industry, fire-fighting systems and power plants.
The document gives instructions for uncrating, transport and storage; installation on site; coupling alignment and piping connections; start-up and shut-down; lubrication; disassembly, repair and reassembly; spare parts; and faults, causes and remedies. It also includes technical data, tightening torques, expected noise values, permissible flange forces and moments, and sectional drawings.
| Speed | up to 3600 rpm |
|---|---|
| Discharge Nozzle | DN 32 up to 200 mm |
| Suction Flanges | EN 1092 - 2 / PN 16 |
| Discharge Flanges | EN 1092 - 2 / PN 40 |
| Operating Temperature | -10 °C up to 110 °C with uncooled soft packing; -10 °C up to 140 °C with cooled soft packing or mechanical seal |
| Ambient Temperature (max) | 40 ºC |
| Casing Pressure (max) | 30 bar (50 bar) |
| Permissible liquids | Clean or slightly contaminated liquids with low viscosities and temperatures up to 140 °C, max. 20 mg/dm³ contamination |
They are suitable for clean or slightly contaminated liquids with low viscosities and temperatures up to 140 °C.
The maximum casing pressure is 30 bar, with 50 bar shown in parentheses.
Disconnect power to the motor and make sure it cannot be switched on accidentally before working on the pump.
SKM is the pump type, 100 is the discharge nozzle in mm, and 6 is the number of stages.