Standart Pompa SKM Series Multistage Centrifugal Pumps Installation, Operation and Maintenance Instructions

This manual is for installation, operation and maintenance of SKM multistage centrifugal pumps. It covers pump description, applications, pump designation, pump nameplate, technical data, etc.


Standart Pompa SKM Series Multistage Centrifugal Pumps Installation, Operation and Maintenance Instructions - cover page
Brand
Standart Pompa
Category
Other
Document type
User Manual
Language
English
Pages
28
File format
PDF
File size
3.7 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
A5E17442D9E912703A5F4BB98FB49E15

About this manual

The Standart Pompa SKM series consists of horizontal ring section multistage centrifugal pumps with closed impellers and diffusers. The manual lists applications including general and municipal water supply, pressurized water supply and booster systems, boiler feed water and condensate, heating and air conditioning, irrigation and sprinkler systems, industry, fire-fighting systems and power plants.

The document gives instructions for uncrating, transport and storage; installation on site; coupling alignment and piping connections; start-up and shut-down; lubrication; disassembly, repair and reassembly; spare parts; and faults, causes and remedies. It also includes technical data, tightening torques, expected noise values, permissible flange forces and moments, and sectional drawings.

What's inside

  • Pump Description
  • Applications
  • Technical Data
  • Uncrating, Transport and Storage
  • Installation on Site
  • Start Up / Shut Down
  • Lubrication
  • Disassembly, Repair and Reassembly
  • Faults, Causes and Remedies
  • Sectional Drawings

Specifications

Speedup to 3600 rpm
Discharge NozzleDN 32 up to 200 mm
Suction FlangesEN 1092 - 2 / PN 16
Discharge FlangesEN 1092 - 2 / PN 40
Operating Temperature-10 °C up to 110 °C with uncooled soft packing; -10 °C up to 140 °C with cooled soft packing or mechanical seal
Ambient Temperature (max)40 ºC
Casing Pressure (max)30 bar (50 bar)
Permissible liquidsClean or slightly contaminated liquids with low viscosities and temperatures up to 140 °C, max. 20 mg/dm³ contamination

Frequently asked questions

What liquids can SKM series pumps handle?

They are suitable for clean or slightly contaminated liquids with low viscosities and temperatures up to 140 °C.

What is the maximum casing pressure?

The maximum casing pressure is 30 bar, with 50 bar shown in parentheses.

What must be done before working on the pump?

Disconnect power to the motor and make sure it cannot be switched on accidentally before working on the pump.

How is the pump designation SKM 100 / 6 interpreted?

SKM is the pump type, 100 is the discharge nozzle in mm, and 6 is the number of stages.

Download PDF (3.7 MB)