This article introduces the features, types, manufacturers, applications, safe use and other information of permanent magnetic lifters.
This Dale guide explains permanent magnetic lifters that attach loads by adhesion. It describes the two permanent magnet types, how the magnetic field is switched on and off, why the magnets are rated for horizontal lifting, and how air gaps reduce capacity.
The guide also covers EN 13155, safe operation and testing, lifting long loads, pros and cons, and safe use. Its manufacturers and models section covers Eclipse Magnets and Yale Magnets, and the document ends with Dale Lifting and Handling Specialists contact details.
| Applicable standard | EN 13155 Cranes— Safety—Non-fixed Load Lifting Attachments |
|---|---|
| Minimum tear off force | At least three times the working load limit |
| Rated lifting orientation | Horizontal plane only |
| Air gap tolerance | Little tolerance of an air gap |
The guide states that permanent lifting magnets should have a tear off force of at least three times the working load limit under the manufacturer's specified conditions.
The document cites the harmonised European Standard EN 13155 Cranes— Safety—Non-fixed Load Lifting Attachments, which covers essential requirements for lifting magnets.
Generally, lifting magnets are designed and rated to lift loads only in the horizontal plane; attempting to use them at an angle may result in the load slipping.
It contains two sets of magnets, one of which can be rotated to reverse its polarity, directing the magnetic field into the load to switch on or internally away from the load to switch off.