About this manual

The manual covers technical specifications, materials and construction, operating principles, installation, first commissioning and start-up, manual flushing, shut-down and draining, and maintenance. It lists models 85107 (¾"), 85101 (1"), 85115 (1½"), 85102 (2"), 85103 (3"), 85104 (4"), 85106 (6"), and 85108 (8").

It explains normal flow and self-cleaning operation, including the flushing valve, hydraulic motor and piston. Maintenance instructions cover protective coating repair and piston lubrication; the document also notes AC/DC controllers and preset differential pressure switch and timer settings.

What's inside

  • Technical Specifications
  • Material Construction
  • Operating Principles
  • Installation
  • First Commissioning and Routine Start-Up
  • Manual Flushing Procedures
  • Shut-Down and Draining Procedures
  • Maintenance
  • Control Diagram AC/DC
  • Parts list

Specifications

Minimum working pressure1–2 bar (15–30 psi)
Maximum working pressure10 bar (150 psi)
Filter housingCarbon steel, electrostatic powder coating
Filtration screensWeave wire mesh, P.V.C. supported
GasketsNatural rubber
Screen grades30–400 micron; 400–30 mesh
Flushing duration for ¾" and 1" models6–8 seconds

Frequently asked questions

What is the maximum working pressure?

10 bar (150 psi).

How often should the piston be lubricated?

Every three months.

How is manual flushing activated?

By depressing the manual button.

What is the minimum inlet pressure during flushing for 6" and 8" models?

2 bar (30 psi).