This file is an underwater light installation manual, which mainly introduces the composition, installation, and use of underwater lights
The Waterpool Industries Standard Series is a halogen underwater floodlight intended for full submersion in fresh-water swimming pools. It is a Class III apparatus operating at 12 V AC, has IPX8 protection at a nominal immersion depth of 2 m, and is stated to comply with EN 60598-2-18 for swimming pool lights.
The manual covers packing contents, general characteristics, installation in concrete and prefabricated pools, assembly, lamp replacement, start-up and safety warnings. It gives mounting guidance such as placing the light about 400–700 mm below the water surface, using a 240 mm hole for prefabricated pools, and never switching the light on unless it is submerged.
| Rated voltage | 12 V AC |
|---|---|
| Lamp | PAR 56, 300 W, 12 V AC |
| Protection class | Class III |
| Degree of protection | IPX8 |
| Nominal immersion depth | 2 m |
| Recommended mounting height | Approximately 400–700 mm from the water surface |
| Hole diameter for prefabricated pools | 240 mm |
| Cable length left wound at the base | 1.5 m |
| Recommended coverage | One 300 W floodlamp per 25–35 m² of water surface |
It uses a PAR56 halogen lamp. The replacement lamp must be PAR56 300 W 12 V with the same characteristics as the supplied lamp.
No. The manual says the light must never be switched on if it is not submerged.
It requires 12 V AC and is to be used only with a safety transformer.
It should be placed about 400–700 mm from the water surface. The manual also recommends positioning it to face away from the usual view to prevent glare.