This file is the operation manual of BOMAX ETRON series manual metering pump. This series of manual metering pumps has the advantages of simple structure, small size, light weight and convenient operation. It can be used in many occasions.
This Portuguese-language manual covers the installation, operation and maintenance of the BOMAX ETRON electromagnetic diaphragm dosing (metering) pump. It explains the on/off operating principle, in which an electronic circuit pulses an electromagnet that moves a self-lubricated PTFE piston and diaphragm, with the flow rate proportional to the pulse frequency, adjustable from 0 up to 150 pulses per minute.
The manual describes the three basic housing models (aluminum with RILSAN paint, ABS plastic for wall mounting, and ABS plastic with pedestal), gives dimensional data and mounting-hole layouts for each, and includes sections on priming, dosing, electrical connection, fuse protection, troubleshooting causes and solutions, removal for overhaul, and the warranty terms. This manual is written in Portuguese.
| Pulse frequency range | 0 to 150 pulses per minute |
|---|---|
| Piston stroke | 0.6 to 1.5 mm |
| Maximum operating pressure | 21 bar (304 psi) |
| Housing type A dimensions | 156 x 220 x 143 mm, 5.5 kg |
| Housing type B dimensions | 120 x 206 x 153 mm, 3 kg |
| Housing type C dimensions | 90 x 140 x 185 mm, 2.5 kg |
| Supply voltage options | 220 VAC, 117 VAC, 24 VAC, 12 VDC, 50–60 Hz |
| Dosing accuracy | ±5% of liters/hour |
| Level sensor contact rating | 10 VA max, 220 VAC, N.O. |
The code on the box has 4 numbers: the first two indicate the pressure in bar and the last two the flow rate in liters/hour. For example, code 0703 means a pump of 3 liters/hour and 7 bar.
The pump stops dosing, prevents air from being drawn into the pump body, and signals the problem with a red LED; an audible alarm is available on request.
Connect it through a Schuko-type outlet with proper grounding, and keep it electrically separated from inductive loads such as motors and solenoid valves, since switching peaks can damage the electronic circuit.
Open the manual priming valve on the dosing head, turn the knob counterclockwise, and let the diaphragm pulses expel the air until product starts to come out of the hose connection, then close the valve. Gloves and protective goggles should always be worn.