This document provides Mobil™ grease replacement recommendations, including general replacement guidelines and recommended inspection procedures.
This document provides general recommendations for replacing Mobil greases. It emphasizes checking the compatibility of the new grease with the existing one, noting that similar thickener types are generally compatible while different types may not be. Users are advised to consult product technical sheets and safety data sheets before replacement. This manual is written in French.
Always check the compatibility of the Mobil grease with the grease already in place; similar thickeners are generally compatible, but different thickeners may not be.
The optimal pneumatic pressure at the grease pump should be between 8 and 10 bars.
Static pressure should be at least 310 bars.
A purge is required when switching to a long-life grease or when the greases are recognized as incompatible.