This document introduces the use instructions of ELSA Compressed Air Escape Breathing Apparatus
This manual gives user instructions for the Sabre ELSA, a self-contained, open circuit, compressed air, constant-flow escape breathing apparatus made by Scott Health and Safety Limited. It covers breathable air requirements, apparatus selection, training and servicing, and describes the hood, the combined reducer/cylinder valve, the 2 litre and 3 litre steel cylinders and the storage bag. Article number 2001225, Issue F, 01.2010.
The second part gives instructions for use and scheduled maintenance: routine checks, after-use cleaning, charging cylinders, and workshop repair and annual servicing. Warnings state that the manual is for trained personnel and that ELSA is an escape apparatus only, not to be used for purposes such as fire fighting or cargo handling.
| Constant flow rate | 38 litres per minute |
|---|---|
| Operating temperature | -15°C to +60°C |
| Water capacity, 10 minute cylinder (CE countries) | 2 L |
| Charging pressure | 200 bar |
| Working pressure | 200 - 10 bar |
| Duration, 10 minute cylinder (CE countries) | 11.5 min |
| Free air capacity, 10 minute cylinder (CE countries) | 400 L |
| Charged weight of complete apparatus, 10 minute cylinder (CE countries) | 4.1 kg |
| Water capacity, 15 minute cylinder (CE countries) | 3 L |
| Duration, 15 minute cylinder (CE countries) | 17 min |
| Charged weight, 15 minute apparatus (CE countries) | 5.3 kg |
The constant flow rate is 38 litres per minute.
No. ELSA is an escape apparatus and must not be used for other purposes such as fire fighting or cargo handling.
The cylinders are charged to 200 bar and have a working pressure of 200 - 10 bar.
ELSA should be operated between -15°C and +60°C.