Dürkopp Adler M-TYPE DELTA Electronic Edge Guide Installation Instructions

This is an installation manual for an electronic edge guide.


Dürkopp Adler M-TYPE DELTA Electronic Edge Guide Installation Instructions - cover page
Brand
Dürkopp Adler
Category
Other
Document type
Installation Guide
Language
English
Pages
16
File format
PDF
File size
1.8 MB
Published
02 November, 2023
Updated
02 November, 2023
MD5 checksum
39D227AC7C67CB32730C170F693EA26E

About this manual

These additional instructions from Dürkopp Adler describe how to install the electronic edge guide on M-TYPE DELTA machines. They cover the contents of kit 4867 590014 (one-axis electronic edge guide) and kit 4867 590024 (two-axis electronic edge guide), followed by the assembly steps for each version, including exchanging the head cover and routing the cable to connections X4 and X105 on the circuit boards.

The document continues with the software settings: activating and calibrating the electronic edge guide, plus checking the circuit board setting. It also lists the travel paths of the edge guides, the dimensions the kits are intended for, and the notes that apply when edge guides not made by Dürkopp Adler are used.

What's inside

  • General information
  • Components of the kit 4867 590014 (one-axis electronic edge guide)
  • Components of the kit 4867 590024 (two-axis electronic edge guide)
  • Assembly
  • Assembling the one-axis electronic edge guide
  • Setting the height of the edge guide
  • Assembling the two-axis electronic edge guide
  • Software settings
  • Activating the electronic edge guide
  • Calibrating the electronic edge guide

Specifications

Lateral travel path1.0 - 45 mm
Vertical travel path0.1 - 12 mm
Intended edge guide axle suspension height15 mm
Intended edge guide width24 mm
Minimum distancesX-axis: 1 mm; Z-axis: 0.1 mm

Frequently asked questions

What dimensions are the electronic edge guide kits intended for?

They are intended for edge guides with an axle suspension height of 15 mm and a width of 24 mm.

What is the travel path of the electronic edge guide?

The lateral travel path is 1.0 - 45 mm and the vertical travel path is 0.1 - 12 mm.

Where is the edge guide cable connected?

The cable is slipped onto connection X4 on the circuit board at the machine arm and onto connection X105 on the circuit board at the edge guide.

Do I have to recalibrate when using edge guides with different dimensions?

Yes, if edge guides with different dimensions are used, you must recalibrate the edge guide.