This document provides basic instruction on the correct operation of the hydraulic lifting system from the perspective of the electrical system.
This document provides instructions for the correct operation of the Aspoeck/Montracon hydraulic lifting deck from an electrical perspective. It details the 24V DC system, including power supply connections, switch controls, and safety protocols. The guide explains how to raise and lower the deck using the PLC-controlled system and describes the functions of various sensors and indicators.
| System Voltage | 24v DC |
|---|---|
| Power Connector Type | Anderson |
| Switch Type | Mechanical momentary type |
| Sensor Range | 4mm |
| Sensor Connector | M12 |
A rapid green flashing LED on the PLC indicates a likely overload or short circuit.
Do not enter under the deck, as one or more locks may not be deployed. Attempt to lift the deck again or consult a service agent.
They should be regularly greased with a non-petroleum based electrical grease.