This is the instruction manual of Atmos DC18SP, DC25SP, DC32SP, DC15EP wood burning boilers.
This instruction manual from ATMOS covers the DC15EP, DC18SP, DC25SP and DC32SP boilers, which are designed for domestic heating with wood and with 6 – 8 mm wood pellets burned in an ATMOS A25 pellet burner. It describes the boiler design, the control panel layout, technical data and drawings, fuel requirements and the accessories supplied.
The manual then gives installation requirements (boiler room, chimney, flue-gas duct, safe distances, connection to the electric network), a set of wiring diagrams for electromechanical regulation and add-on modules, and the operating instructions for wood and pellet burning, output setting, cleaning, use and inspections, troubleshooting and spare parts.
| Suitable building heat loss | 5 - 35 kW |
|---|---|
| Pellet diameter | 6 – 8 mm |
| Firewood length | 330 - 530 mm |
| Boiler drum steel sheet thickness | 3 - 6 mm |
| Fuse | 6,3A 5x20/T6,3A/1500 - type H |
| Operating water temperature in the boiler | 80 - 90 °C |
| Minimum return water temperature | 65 °C |
| Recommended firewood moisture | 12 - 20 % |
| Recommended equalising tank volume | 500 – 1000 l |
The boilers are designed for domestic heating using wood and good quality wood pellets of 6 – 8 mm diameter. They are not intended for burning saw dust or small-particle wood waste, which can only be burnt in small quantities together with log firewood.
The water returning to the boiler must be kept at a minimum of 65 °C, so a Laddomat 21/22 or a thermoregulatory valve has to be installed behind the boiler.
Only dry fuel wood with 12 - 20 % moisture content should be used; higher moisture content decreases performance and increases consumption.
The guarantee period for the boiler drum is extended from 24 to 36 months when the boiler is installed with a Laddomat 21/22 or a TV 60 °C thermoregulatory valve and accumulation tanks.