record DFA 127 Automatic Swing Door Operator Manual

This document is a manual for the automatic swing door operator DFA 127. It mainly introduces the characteristics and features of the product, such as the structure and function of the product, installation methods, operating instructions, etc.


record DFA 127 Automatic Swing Door Operator Manual - cover page
Brand
Record
Category
Automation control Equipment
Document type
User Manual
Language
English
Pages
55
File format
PDF
File size
1.9 MB
Published
02 November, 2023
Updated
02 November, 2023
MD5 checksum
7A729CB49905B6C115F5983D74123B48

About this manual

This manual covers the record DFA 127 (Full Power), a compact, microprocessor-controlled automatic swing door operator. The door movement is controlled by the microprocessor, which evaluates the current door position, the door speed and the final position, and the operator is designed to close without electrical power using the energy stored in the spring, with the motion damped by the motor acting as a generator.

The document describes the equipment and its construction, safety instructions, technical data, types of arms (standard and slide arms) and lever adapters, installation instructions and assembly dimension diagrams, commissioning, operating instructions, configurations, Master/Slave applications, status and fault signals for the BDE-D, maintenance instructions, cable layout and wiring diagrams.

What's inside

  • Description of the equipment
  • Safety Instructions
  • Technical Data
  • Construction and Function
  • Types of arms
  • Lever adapters for arms
  • Installation instructions for standard arms
  • Installation instructions for slide arms
  • Assembly dimension diagrams
  • Installation

Specifications

Dimensions (operator)600 x 85 x 124 mm (w x h x d)
Operating voltage230 V~
Power consumptionStandby 13 W, rated power 67 W
Max. torque50 Nm
Opening angleAdjustable from 70° to 115°
Time delayAdjustable from 0 to 20 seconds
Opening speedAdjustable from 3 to 20 seconds
Closing speedAdjustable from 5 to 20 seconds
Temperature range-15 to +50 °C
Humidity rangeUp to 85% relative humidity, non condensing
Max. mass moment of inertia (standard arms)65 kgm2

Frequently asked questions

What is the operating voltage of the record DFA 127?

The operator runs on 230 V~ mains voltage.

What is the maximum torque of the DFA 127?

The maximum torque is 50 Nm.

Can two DFA 127 operators be used in Master/Slave operation on fire protection doors?

No. Master/Slave operation is not suitable for fire protection doors.

Who is allowed to install, maintain or repair the DFA 127?

Installation, maintenance and repairs may only be carried out by qualified and authorised personnel.