Blue-White Industries, Ltd. Variable Area Flow Meters
This technical data sheet describes the Blue-White Industries F-440 series variable area flow meters. The meters use a polysulfone meter body with a rod-guided float (316SS, PVC, or Teflon depending on model), union connections, and a direct reading permanent scale in a compact size for tight installation spaces. Three series are covered: the Standard Series with a 316SS guide rod, the K-Series with a Hastelloy guide rod for highly corrosive applications, and the Solarmeter Series with brass adapters, available for in-line installations only.
The document lists materials of construction, dimensions for 3/8", 1/2", and 3/4" pipe sizes, flow ranges in GPM, GPH, LPM, and LPH, and model numbers for in-line mount, panel mount, and panel mount adjustable versions. Installation requirements warn that the meter must be mounted in an exact vertical plane, that only Teflon tape may be used on threaded adapters (no pipe dope or PVC glue), and that maximum working pressure and fluid temperature are interdependent per the temperature vs. pressure chart.
| Meter body material | Polysulfone |
|---|---|
| Float / guide rod | 316SS or Hastelloy rod guided float |
| Max. working pressure | 150 PSI (10.3 bar) @ 70 F (21 C) |
| Max. fluid temperature (standard units) | 212 F (100 C) @ 0 PSI |
| Max. fluid temperature (Solarmeter units) | 240 F (115 C) @ 0 PSI |
| Full scale accuracy | +/- 5% |
| Calibration fluid | Water, specific gravity 1.0 |
| Scale length | 2" (50mm) |
| Maximum pressure drop | 2 PSI |
| Approximate shipping weight | 0.5 lb. (.23 kg) |
| O-ring seals | Viton (optional EP) |
The flowmeter must be installed in an exact vertical plane; misalignment can damage the meter and cause the o-ring seals to leak.
No. Use only Teflon tape on the threaded adapters; pipe dope and PVC glue (even fumes) can severely damage the meter body and plastic fittings.
Not unless the meter is protected against sudden bursts of flow, since a sudden burst can drive the float into the float stop with destructive force.
Liquid models are calibrated with water at specific gravity 1.0; custom specific gravity calibrations are available from the factory.