This is an operating manual that introduces the operation methods of STAUFF's SWG-WI06 pneumatic arc stud welder, including the components of the device, safety precautions for use, operation manual and maintenance and maintenance.
This operating manual describes the STAUFF SWG-WI06 stud welding machine. It is a translation of the original operating manual, issue 2016-06, and is intended for qualified personnel who are trained and authorized to work with the machine.
The manual covers safety precautions, scope of supply, technical data, intended use, components, the drawn-arc stud welding process, workplace preparation, connections, welding parameter settings, weld quality checks, troubleshooting, shutdown, maintenance, storage and disposal.
| Welding process | Drawn-arc stud welding |
|---|---|
| Noise level during stud welding | > 90 dB (A) |
Do not operate the stud welding machine if you have a heart pacemaker, and do not remain in its vicinity during welding.
Never weld in rooms with a ceiling height of less than 3 m.
It is intended for qualified personnel with technical training, know-how and experience.
The manual describes drawn-arc stud welding.