VIVREAU PURITY 450 Quell ST, 600 Quell ST and 1200 Quell ST Water Filter System Manual

This manual provides instructions for installing, cleaning, and maintaining your water filter system.


VIVREAU PURITY 450 Quell ST, 600 Quell ST and 1200 Quell ST Water Filter System Manual - cover page
Brand
Vivreau
Category
Other products
Document type
User Manual
Language
English
Pages
59
File format
PDF
File size
3.4 MB
Published
01 November, 2023
Updated
01 November, 2023
MD5 checksum
94665C2AA5F9BCE48AF09BADFD08C5EB

About this manual

The VIVREAU PURITY 450, 600 and 1200 Quell ST Water Filter System removes carbonate hardness from drinking water to prevent limescale in downstream appliances. It is available in three sizes, with or without Advanced Control System measuring and display electronics, for applications such as coffee and espresso machines, vending machines, steam ovens and air humidifiers.

The manual covers installation, commissioning, filter replacement, capacity, repair, query mode, troubleshooting, battery information and technical data. It states that only drinking-water-quality cold water may be used and gives flushing volumes after stagnation periods.

What's inside

  • Definition of Terms
  • General Information
  • Operating and Safety Information
  • Installation
  • Commissioning a New Filter
  • Replacing the Filter Cartridge
  • Filter Capacity
  • Repair
  • Troubleshooting
  • Technical Data

Specifications

Warranty2 years
Pressure vessel and lid service lifeUp to 10 years
Hose replacement intervalMaximum 5 years
Filter cartridge maximum usage period12 months
Intake water qualityDrinking water quality
Water filtrate classificationCategory 2 according to DIN EN 1717
Flushing after 2-3 days stagnation (PURITY 450)6 litres (1.6 US gallons)
Flushing after over 4 weeks stagnation (PURITY 450)30 litres (8.0 US gallons)

Frequently asked questions

What warranty applies to the VIVREAU PURITY filter system?

The filter system is subject to a statutory warranty of 2 years.

What water may be used as intake water?

Only water of drinking water quality may be used.

How long may the pressure vessel and lid be used?

They have a service life of up to ten years from installation and must be replaced after a maximum of ten years.

How much water should be flushed through a PURITY 450 after 2-3 days of non-use?

At least 6 litres (1.6 US gallons).