This manual describes how to use the Sprue ST-625 smoke alarm.
This user manual describes the FireAngel ST-625 smoke alarm from Sprue Safety Products Ltd. The ST-625 is a multi-criteria detector that combines an optical sensing chamber with thermal enhancement (Thermoptek technology), giving a fast response to both slow smouldering and fast flaming fires without using ionisation sources.
The manual explains where the alarm may be installed (existing homes, mobile homes and caravans, individual rooms in institutions with a primary detection system), how to install the batteries and base plate, how the alarm operates, how to replace batteries, how to run the weekly alarm test, and how the Smart Silence and Sleep Easy features work. It also covers maintenance, troubleshooting, disposal and warranty information.
| Standard | EN 14604:2005 + AC:2008 |
|---|---|
| Sensor technology | Thermoptek (optical sensing with thermal enhancement) |
| Recommended replacement batteries | Energizer E91, Duracell MN1500, Panasonic ProPower LR6 (alkaline) |
| Standby LED indication | Red LED flashes every 40 seconds |
| Smart Silence duration | Approximately 10 minutes reduced sensitivity |
| Sleep Easy silence duration | 8 hours, repeatable up to 10 times |
The manual states you should test your smoke alarm every week by firmly pressing the test button in the centre and releasing it.
After briefly pressing the test button, the alarm silences and enters a reduced sensitivity mode for approximately 10 minutes, then automatically returns to full sensitivity.
In a low battery condition the unit emits an audible chirp once every 40 seconds and continues to warn for at least 7 days.
Only alkaline Energizer E91, Duracell MN1500 or Panasonic ProPower LR6 batteries should be used; other batteries may affect the alarm's operation.