EVPK90 Linear Extractor Manual for Installation, Use and Maintenance
This manual covers the CDA EVPK90 linear extractor, including control panel operation, care and maintenance, grease and charcoal filter cleaning or replacement, light replacement, electrical connection, mounting, ducting and troubleshooting.
It also states electrical requirements, minimum clearances above electric and gas hobs, recommended ducting diameters, cleaning precautions and filter reset steps.
| Mains electrical voltage | 230 – 240Vac, 50Hz |
|---|---|
| Total rated power consumption | 330W |
| Light bulb | 12V 20W halogen |
| Fuse | 3A |
| Minimum distance above electric hob | exceed 600mm (650mm recommended) |
| Minimum distance above gas hob | exceed 700mm (750mm recommended) |
| Minimum distance without gas hob instructions | at least 760mm |
| Recommended ducting diameter | 150mm |
| Alternative ducting diameters | 100mm or 120mm |
Touch key A.
It runs for ten minutes before returning to the previously selected speed.
Touch key E; the extractor then runs for 15 minutes before switching off automatically.
Touch key A for approximately five seconds, until the letter A stops flashing.